Summary for Test 2018-06-15-9-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/15/2018 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/19/2018 |
| Sample type | Quality Assurance | A brief description of the sample | 5/8 inch anchor bolt |
| The quantity of what the sample constitutes | 280 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | A | Last name of sampler or witnessed by | Contreras |
| Title of sampler | Caltrans Inspector | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Nucor Steel | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L103-017-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | PL17102750 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F1554 | |
| Bolt Length(s) | 24" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | HDG |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | PL1710275052 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-06-15-9
DIME Test ID: 2018-06-15-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-06-28
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/20/2018
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | F1554 Gr 55 Rod | 0.226 | 18978 | 84 | 83974 | 61321 | 13858 | F1554 Gr 55 Rod |
General comments (publicly viewable) (Max 1000 characters): F1554 Gr 55 Rod
Test Graph
Source: Partner Data Point FileTest was verified on 6/21/2018 ✔