Summary for Test 2018-05-22-15-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/22/2018 | Sample Unique Key | 15 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/01/2018 |
| Sample type | Stock | A brief description of the sample | A325 HDG Bolt |
| The quantity of what the sample constitutes | 17 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Williams |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Ameron International | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | RC148643 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 387906C | |
| Washer Mfg. Lot Number(s) | 308003 | Bolt Specification | A325 |
| Bolt Length(s) | 1" x 5.5", .625" x 2.0", 1" x 2.5", 1" x 4", | Nut Specification | A563 |
| Washer Specification | F436 | Finish | F2329 |
| Diameter/Size | 1", .625", 1.25" | Bolt Mfg. Lot Number | 761555,396151A, 393606A, 799628, 768723 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Green | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-05-22-15
DIME Test ID: 2018-05-22-15-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-06-19
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/08/2018
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 761555 | 1\" | 91007 | 404.8 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 6/12/2018 ✔