Summary for Test 2018-05-17-13-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date05/17/2018 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing05/23/2018 Sample typeQuality Assurance
A brief description of the samplesize 8 flashwelded hoop The quantity of what the sample constitutes450
From where was the sample collectedFabricator First name of sampler or witnessed byPrakash
Last name of sampler or witnessed byPatel Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) NumberC952777 Inspector Lot Number from the Transportation Laboratory (TL) FormL11-009-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)65027876
Hoop Manufacturer Lot Number(s)7 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop5'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGERDAUE
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2018-05-17-13
DIME Test ID: 2018-05-17-13-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-05-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/23/2018
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
127#8/25mm0.797621096470Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/23/2018 ✔