Summary for Test 2026-08-18-9-5

Test performed: CTM 321-0

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/18/2026 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeInformational A brief description of the samplehalf inch HMA sample
The quantity of what the sample constitutes200 From where was the sample collectedSource
First name of sampler or witnessed byJohn Last name of sampler or witnessed byDoe
Title of sampler Telephone number of samplerNot set
Laboratory sample identification-694408626 Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameStonemont Solutions Transportation Laboratory (TL) NumberNot set
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix NumberD35AC6531
Binder content (%)2.4 Virgin binder PGPG 70-10
Design binder PG Binder SupplierValero
RAP content (%)14 WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-08-18-9
DIME Test ID: 2026-08-18-9-5
Testing Lab: Stonemont Solutions, Incorporated
Test Method: CTM 321-0: New Test Method for Determination of Rutting Resistance Using High Temperature Indirect Tensile (HT-IDT) Strength of Asphalt Mixtures
Test Release Date: 2026-08-18

Test Results


Number of specimens: 1
Specimen Preparation method: Field Cores
Input Type: Calculated
Tester's full name: John Doe
Date of test: 08/18/2026
1
1
CT 320 Reheat 1 hour at 135C
oven chamber
135 C
5 min
7.1 %
150.0 mm
63 mm
135 C
2 mm/min
14000.0 N

935.7 kPa

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/18/2026