Summary for Test 2026-08-18-9-4
Test performed: CTM 389-19Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/18/2026 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
| Sample type | Informational | A brief description of the sample | half inch HMA sample |
| The quantity of what the sample constitutes | 200 | From where was the sample collected | Source |
| First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Doe |
| Title of sampler | Telephone number of sampler | Not set | |
| Laboratory sample identification | -694408626 | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | Stonemont Solutions | Transportation Laboratory (TL) Number | Not set |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | D35AC6531 |
| Binder content (%) | 2.4 | Virgin binder PG | PG 70-10 |
| Design binder PG | Binder Supplier | Valero | |
| RAP content (%) | 14 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-18-9
DIME Test ID: 2026-08-18-9-4
Testing Lab: Stonemont Solutions, Incorporated
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2026-08-18
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method: Field Cores
Input Type: Calculated
Tester's full name: John Doe
Date of test: 08/18/2026
Average impression at 5000 passes (left/right avg): 12.9 mm
Average impression at 10000 passes (left/right avg): 13.1 mm
Average impression at 15000 passes (left/right avg): 13.3 mm
Raw Data: no data
Average impression at 20000 passes (left/right avg): no data
Average impression at 25000 passes (left/right avg): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2026 ✔