Summary for Test 2026-07-22-55-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 993331 DEA: 023H6904 EFIS: 0218000010 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-89-30/R42.1 |
| Award Date | 11/21/2024 |
| Closeout Date | Not set |
| Work Description | ALMANOR WEST REHAB - ROADWAY REHABILITATION |
| Location Description | IN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36. |
| QA Service Level | 1 (Verified on 10/14/2021) |
Sample Information
| Sample Taken Date | 07/22/2026 | Sample Unique Key | 55 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/23/2026 | Sample type | Preliminary |
| A brief description of the sample | Sand, Silt, Rock, and Soil | The quantity of what the sample constitutes | 1 Container Sand, Silt, Rock and Soil |
| From where was the sample collected | Source | First name of sampler or witnessed by | Colt |
| Last name of sampler or witnessed by | Sweeny | Title of sampler | MREA |
| Telephone number of sampler | Laboratory sample identification | D80304 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | D2 Mat Lab | |
| Transportation Laboratory (TL) Number | 002 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Shoulder at outlet PM 4.0, PLU-89. | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-07-22-55
DIME Test ID: 2026-07-22-55-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2026-08-04
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/03/2026
Minimum soil resistance of the lab measurement: 7700 Ohms
Soil sample temperature: 19 C
Soil box constant: 1
pH of soil: 6.31
Minimum soil resistance corrected to 15.5: 8373.75 Ohm-cm
Minimum soil resistivity at 15.5: 8374 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.31, p=8374.Ω∙cm
Test was verified on 8/4/2026 ✔