Summary for Test 2026-07-22-54-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 993331
DEA: 023H6904
EFIS: 0218000010
DIST-CO-RTE-PM02-PLU-89-30/R42.1
Award Date11/21/2024
Closeout DateNot set
Work DescriptionALMANOR WEST REHAB - ROADWAY REHABILITATION
Location DescriptionIN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36.
QA Service Level1 (Verified on 10/14/2021)

Sample Information

Sample Taken Date07/22/2026 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/23/2026
Sample typePreliminary A brief description of the sampleSand, Silt, Rock, and Soil
The quantity of what the sample constitutes1 Container Sand, Silt, Rock and Soil From where was the sample collectedSource
First name of sampler or witnessed byColt Last name of sampler or witnessed bySweeny
Title of samplerMREA Telephone number of sampler
Laboratory sample identificationD80303 Linked DIME Sample ID
The fabricator/manufacturer/facility nameD2 Mat Lab Transportation Laboratory (TL) Number001
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedShoulder at outlet PM 3.8, PLU-89.
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2026-07-22-54
DIME Test ID: 2026-07-22-54-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2026-08-04

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/03/2026
Minimum soil resistance of the lab measurement: 3000 Ohms
Soil sample temperature: 18.3 C
Soil box constant: 1
pH of soil: 6.09
Minimum soil resistance corrected to 15.5: 3210 Ohm-cm
Minimum soil resistivity at 15.5: 3210 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.09, p=3210.Ω∙cm

Test was verified on 8/4/2026