Summary for Test 2026-07-07-106-6

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 993331
DEA: 023H6904
EFIS: 0218000010
DIST-CO-RTE-PM02-PLU-89-30/R42.1
Award Date11/21/2024
Closeout DateNot set
Work DescriptionALMANOR WEST REHAB - ROADWAY REHABILITATION
Location DescriptionIN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36.
QA Service Level1 (Verified on 10/14/2021)

Sample Information

Sample Taken Date07/07/2026 Sample Unique Key106
Date that the sample was received by the laboratory/organization performing the testing07/08/2026 Sample typeProduction Start-Up
A brief description of the sample16 boxes of Lime Treated 1/2-inch Type A HMA (eq. PG 64-28) The quantity of what the sample constitutesProduction Start Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byBrandon
Last name of sampler or witnessed byWhite Title of samplerTET
Telephone number of sampler Laboratory sample identificationD80266
Linked DIME Sample ID The fabricator/manufacturer/facility nameDig It Construction — Sierra Cascade Aggregate and Asphalt Products (Chester, CA)
Transportation Laboratory (TL) Number896860 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)5.8 Virgin binder PG
Design binder PG PG 64-28M Binder SupplierAlbina (Klamath Falls, OR)
RAP content (%)21 WMA AdditivesNo
Antistrip type1.0% Lime

Test Details

DIME Sample ID: 2026-07-07-106
DIME Test ID: 2026-07-07-106-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2026-08-03

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?: Lab compacted
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/13/2026
123
2.372 2.367 2.366
2.442

2.9 %

3.1 %

3.1 %

3.0 %
General comments (publicly viewable) (Max 1000 characters): AASHTO T 269: Pa=3.4% Allowed tolerance for air voids is 2.5 – 5.5%.

Test was verified on 8/3/2026 ✔