Summary for Test 2026-07-06-96-3
Test performed: AASHTO T308-10Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/06/2026 | Sample Unique Key | 96 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2026 |
| Sample type | Informational | A brief description of the sample | half inch HMA sample |
| The quantity of what the sample constitutes | 150 | From where was the sample collected | Source |
| First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Doe |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 1360000571 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Stonemont Solutions | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | E78AC4578 |
| Binder content (%) | 3.1 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | 14 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-07-06-96
DIME Test ID: 2026-07-06-96-3
Testing Lab: Stonemont Solutions, Incorporated
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-08-12
Test Results
What temperature unit is used?: Celcius
Input Type: Calculated
Tester's full name: John Doe
Date of test: 07/06/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1468.0 g
Mass Loss: 91.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.25 %
Moisture Content: 0.50 %
Temperature Compensation Factor: 0.51 %
Corrected Asphalt Binder Content: 5.00 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/12/2026 ✔