Summary for Test 2026-07-15-69-1
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 993331 DEA: 023H6904 EFIS: 0218000010 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-89-30/R42.1 |
| Award Date | 11/21/2024 |
| Closeout Date | Not set |
| Work Description | ALMANOR WEST REHAB - ROADWAY REHABILITATION |
| Location Description | IN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36. |
| QA Service Level | 1 (Verified on 10/14/2021) |
Sample Information
| Sample Taken Date | 07/15/2026 | Sample Unique Key | 69 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/16/2026 | Sample type | Production Start-Up |
| A brief description of the sample | 1 Bag RAP | The quantity of what the sample constitutes | Production Start Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Brandon |
| Last name of sampler or witnessed by | White | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | D80292B | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Dig It Construction – Sierra Cascade Aggregate and Asphalt Products (Chester, CA) | |
| Transportation Laboratory (TL) Number | 848648 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Dig It Construction |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2026-07-15-69
DIME Test ID: 2026-07-15-69-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-07-29
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/21/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7330.6 grams
Mass of oven-dry sample in air for Sample 1: 2544.7 grams
Mass of container filled with the sample and water for Sample 1: 8861.4 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.51
Theoretical maximum density at 25°C (77°F): 2502.7 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.510,
Gser≈2.716
Test was verified on 7/29/2026 ✔