Summary for Test 2026-07-07-103-1

Test performed: AASHTO T315-24

Project Information

Project IdentifiersProject ID: 993331
DEA: 023H6904
EFIS: 0218000010
DIST-CO-RTE-PM02-PLU-89-30/R42.1
Award Date11/21/2024
Closeout DateNot set
Work DescriptionALMANOR WEST REHAB - ROADWAY REHABILITATION
Location DescriptionIN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36.
QA Service Level1 (Verified on 10/14/2021)

Sample Information

Sample Taken Date07/07/2026 Sample Unique Key103
Date that the sample was received by the laboratory/organization performing the testing07/24/2026 Sample typeQuality Assurance
A brief description of the sample64-16 The quantity of what the sample constitutes1 CAN OF 64-16
From where was the sample collectedSource First name of sampler or witnessed byBRANDON
Last name of sampler or witnessed byWHITE Title of samplerTET
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDIG IT CONSTURCTION
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form896864
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierDig it Construction, Chester Plant
Certified Asphalt SupplierAlbina Asphalt - Klamath Falls - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNOT LISTED ON TL101 HMA Supplier Mix ID NumberNOT LISTED ON TL 101

Test Details

DIME Sample ID: 2026-07-07-103
DIME Test ID: 2026-07-07-103-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2026-07-29

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Amare Tefera
Date of test: 07/27/2026
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.06 %
Stress Amplitude: 0.118 kPa
Phase Angle (δ) (for the 10 cycles): 86.2 degree
Complex Modulus (G*) (for the 10 measurements): 0.981 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 0.98 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/29/2026 ✔