Summary for Test 2026-07-07-89-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 993331
DEA: 023H6904
EFIS: 0218000010
DIST-CO-RTE-PM02-PLU-89-30/R42.1
Award Date11/21/2024
Closeout DateNot set
Work DescriptionALMANOR WEST REHAB - ROADWAY REHABILITATION
Location DescriptionIN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36.
QA Service Level1 (Verified on 10/14/2021)

Sample Information

Sample Taken Date07/07/2026 Sample Unique Key89
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/08/2026
Sample typeProduction Start-Up A brief description of the sample2 bags of RAP
The quantity of what the sample constitutesProduction Start Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD80265B Linked DIME Sample ID
The fabricator/manufacturer/facility nameDig It Chester Transportation Laboratory (TL) Number896859
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceDig It Construction
Aggregate Size Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2026-07-07-89
DIME Test ID: 2026-07-07-89-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-07-16

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/10/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7330.6 grams
Mass of oven-dry sample in air for Sample 1: 1544.7 grams
Mass of container filled with the sample and water for Sample 1: 8252.8 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.481
Theoretical maximum density at 25°C (77°F): 2473.8 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.481, Gser≈2.758

Test was verified on 7/16/2026