Summary for Test 2018-02-14-4-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date02/14/2018 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing02/14/2018 Sample typeQuality Control
A brief description of the sample1 gallon can The quantity of what the sample constitutes10 Tankers
From where was the sample collectedSource First name of sampler or witnessed byChris
Last name of sampler or witnessed byNunes Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameKwik bond and Reichhold
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1101774
Batch Number1101774 Mix number1101774

Test Details

DIME Sample ID: 2018-02-14-4
DIME Test ID: 2018-02-14-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2018-02-26

Test Results


Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 02/26/2018
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 101 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.079
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 60.6 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2882 psi
Styrene ASTM D 2369 40% to 50 %: 46.12 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 711 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.17 grams
General comments (publicly viewable) (Max 1000 characters): batch 00001101774: material is satisfactory for use (accepted suppliers test result)

Test was verified on 4/19/2018