Summary for Test 2018-03-20-8-3
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/20/2018 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/28/2018 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
| The quantity of what the sample constitutes | 5 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Williams |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Ameron International | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 1373701 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | Unytite | |
| Washer Mfg. Lot Number(s) | 305695 | Bolt Specification | A325 |
| Bolt Length(s) | 5.5 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | F2329 |
| Diameter/Size | 1 | Bolt Mfg. Lot Number | 761555 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-03-20-8
DIME Test ID: 2018-03-20-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-04-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/29/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 27136-177895 | 1\" | 93357 | 415.27 | Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 3/30/2018 ✔