Summary for Test 2018-03-20-1-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/20/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2018 |
| Sample type | Recertification | A brief description of the sample | Resistance Butt Welded Hoops |
| The quantity of what the sample constitutes | 10 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
| Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Harris Rebar, Nucor | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-119-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1202000411 |
| Hoop Manufacturer Lot Number(s) | B10SP2 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 8 |
| Diameter of Hoop | 6'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Utah |
| Welding Company | Harris Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-03-20-1
DIME Test ID: 2018-03-20-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-04-23
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/23/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Cycle-2 | 100 | #8/25mm | 10599 | 0.79 | 79305 | 100386 | NECKING OK | Fred |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 4/16/2018 ✔