Summary for Test 2018-03-06-11-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211784
DEA: 11085784
EFIS: 1100000064
DIST-CO-RTE-PM11-SD-163-4.1/4.9
Award Date06/16/2017
Closeout Date08/10/2021
Work DescriptionINTERCHANGE MODIFICATION AND OVERCROSSING WIDENING.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING
QA Service Level1 (Verified on 09/05/2017)

Sample Information

Sample Taken Date03/06/2018 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing03/09/2018 Sample typeQuality Assurance
A brief description of the samplesize 18 bar with HRC 410/490 couplers The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byAlex
Last name of sampler or witnessed byBalce Title of samplerCT CTR Rep
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC HRC
Transportation Laboratory (TL) NumberC958033 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size18 Coupler Model410 490
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)NF100788861 NF100886179 Rebar Heat Number(s)6502175306 3058432 308013 6502035104
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-03-06-11
DIME Test ID: 2018-03-06-11-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-03-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/12/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
141#18/57mm4038388195970necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 3/12/2018 ✔