Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-03-06-11

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211784
DEA: 11085784
EFIS: 1100000064
DIST-CO-RTE-PM11-SD-163-4.1/4.9
Award Date06/16/2017
Closeout Date08/10/2021
Work DescriptionINTERCHANGE MODIFICATION AND OVERCROSSING WIDENING.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING
QA Service Level1 (Verified on 09/05/2017)

Sample Information

Sample Taken Date03/06/2018 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/09/2018
Sample typeQuality Assurance A brief description of the samplesize 18 bar with HRC 410/490 couplers
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byAlex Last name of sampler or witnessed byBalce
Title of samplerCT CTR Rep Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC HRC Transportation Laboratory (TL) NumberC958033
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size18 Coupler Model410 490
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)NF100788861 NF100886179 Rebar Heat Number(s)6502175306 3058432 308013 6502035104
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-03-06-11-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/12/2018Brian
Yes
03/19/2018necking okay
2018-03-06-11-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/12/2018Brian
Yes
03/19/2018Brittle Break
2018-03-06-11-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/12/2018Brian
Yes
03/19/2018necking okay
2018-03-06-11-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory03/12/2018Brian
Yes
03/19/2018necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-03-06-11-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-03-06-11-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-03-06-11-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-03-06-11-4 CTM 670-December 2013 (Verified)