Summary for Test 2018-01-31-18-2
Test performed: ASTM A416-15Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/31/2018 | Sample Unique Key | 18 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jim | Last name of sampler or witnessed by | Hoenig |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Insteel Wire Stressteel | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
| Group Number | Unknown | Strand Diameter | .6 in |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | 18100266 | Mfg. Lot Number(s) | NA |
| Manufacturer(s) | Insteel |
Test Details
DIME Sample ID: 2018-01-31-18
DIME Test ID: 2018-01-31-18-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-02-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 02/20/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88768
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 18100266 | 1301468160692 | 0.218 | 61742 | 56514 | 28.8 | 1.53 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 2/20/2018 ✔