Summary for Test 2025-10-09-101-1

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 994654
DEA: 07313504
EFIS: 0715000090
DIST-CO-RTE-PM07-LA,VEN-1-37.7/62.9,0.0/0.9
Award Date07/20/2023
Closeout DateNot set
Work DescriptionREMOVE AND CONSTRUCT BRIDGE AND CULVERTS.
Location DescriptionLOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS FROM 0.4 MILE SOUTH OF TEMESCAL CANYON ROAD TO 0.1 MILE NORTH OF TONGA STREET
QA Service Level1 (Verified on 07/24/2023)

Sample Information

Sample Taken Date10/09/2025 Sample Unique Key101
Date that the sample was received by the laboratory/organization performing the testing10/10/2025 Sample typeQuality Control
A brief description of the sample 1"x no.4, 3/8, rock and sand The quantity of what the sample constitutes1 Bag
From where was the sample collectedJob Site First name of sampler or witnessed byErik
Last name of sampler or witnessed byVillalba Title of samplerQC Field Technician
Telephone number of sampler Laboratory sample identificationSL675350CE
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameAssociated Ready Mix
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier00-0000 Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sampleSet 1 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberSL675350CE Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-10-09-101
DIME Test ID: 2025-10-09-101-1
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2026-02-26

Test Results


Describe the gradation of the aggregate or the test method:: Mix of sizes - max 1.5 in.
Input Type: Calculated
Tester's full name: Julian Prieto
Date of test: 10/10/2025
Cleanness value (11/2 in. maximum aggregate mix): 70
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/26/2026 ✔