Summary for Test 2018-01-06-2-4

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209217
DEA: 080F5404
EFIS: 0800000136
COOP: 081468
DIST-CO-RTE-PM08-RIV-91,15-0.0/13.04, 35.64/45.14
Award Date09/09/2013
Closeout Date09/20/2023
Work DescriptionSR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
QA Service Level1 (Verified on 08/07/2014)

Sample Information

Sample Taken Date01/06/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing01/07/2018 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byY
Last name of sampler or witnessed byRETA Title of samplerTE
Telephone number of samplerUnknown Laboratory sample identification888-SRL408
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHolliday Rock CHINO
Transportation Laboratory (TL) NumberSRL408 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCM4261
The truck number from where the sample was collected316 The batch plant ticket number from where the sample was collected118067375
Concrete batch plantNP The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 6 Where the material sample would have been placed if not sampledAREA 2
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-01-06-2
DIME Test ID: 2018-01-06-2-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-02-05

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 02/03/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Maximum load on cylinder 1: 236535 lb
Type of fracture pattern of cylinder 1: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 30 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Compressive strength of cylinder (to nearest 10 psi): 8370 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/5/2018 ✔