Summary for Test 2025-08-11-93-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1000101 DEA: 081J2904 EFIS: 0818000015 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-215-25.0/R31.2 |
| Award Date | 06/18/2024 |
| Closeout Date | Not set |
| Work Description | RHMA, HMA, REPLACE AC SURFACING, AND COLD PLANE AC PVMT. |
| Location Description | RIVERSIDE COUNTY IN AND NEAR PERRIS FROM 0.1 MILE SOUTH OF SAN JACINTO RIVER BRIDGE TO 0.3 MILE NORTH OF RAMONA EXPRESSWAY |
| QA Service Level | 1 (Verified on 05/15/2024) |
Sample Information
| Sample Taken Date | 08/11/2025 | Sample Unique Key | 93 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/11/2025 | Sample type | Acceptance |
| A brief description of the sample | Class II Aggregate Base | The quantity of what the sample constitutes | 24.9 kg |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Gabriel |
| Last name of sampler or witnessed by | Ramirez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Ramona Expy to SB I-215 On-Ramp, Gore Area, Sta "AHD" 201+54 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-08-11-93
DIME Test ID: 2025-08-11-93-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-02-18
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Gabriel Ramirez
Date of test: 08/11/2025
Gage No.: 36636
Test No.: 1
Nuclear By: Gabriel Ramirez
Non-Bias Plan No.: 1
Depth: 3"
Material No.: no data
Material Type: Class II Aggregate Base
Impact By: Gabriel Ramirez
Standard Count Density: 1711 g/cc
Count or Density 1: 2417 g/cc
Count or Density 2: 2433 g/cc
Count or Density 3: 2437 g/cc
Standard Count Moisture: 639 g/cc
Moisture Count 1: 101 g/cc
Moisture Count 2: 106 g/cc
Moisture Count 3: 102 g/cc
Sum of Count or Density: 7287 g/cc
Average of Count or Density: 2429 g/cc
Sum of Moisture Count: 309 g/cc
Average of Moisture Count: 103 g/cc
Count Ratio Density: 1.42
Count Ratio Moisture: 0.16
Calculated Percent Relative Compaction: 96.1 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters): Density Spec 95%
Test was verified on 2/18/2026 ✔