Summary for Test 2018-01-12-5-7
Test performed: AASHTO T210-15Project Information
| Project Identifiers | Project ID: 99999 DEA: 0322222 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 01/12/2018 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/12/2018 |
| Sample type | Verification | A brief description of the sample | Combined, Untreated, 3/4-inch Type A |
| The quantity of what the sample constitutes | JMF | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | a | Last name of sampler or witnessed by | a |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | SNC - Mustang Asphalt Plant | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | MSHA IDs 2602089 and 2602404 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | 5202 |
| The plant number | Unknown | A detailed description of where the material sample was collected | Lab-batched from untreated stockpiles |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Unknown | Lot number | Not set |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2018-01-12-5
DIME Test ID: 2018-01-12-5-7
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Test Release Date: 2018-01-24
Test Results
Which test procedure(s) is/are used?: Procedure B
Input Type: Measured
Tester's full name: Ward Jenkins
Date of test: 01/17/2018
Was strict temperature control maintained?: Yes
What type of water was used?: Distilled
Clay reading: 5.3 in
Sand reading: 4 in
Durability Index (fine): 76
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/17/2018 ✔