Summary for Test 2025-10-27-51-3

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000540
DEA: 051Q03U4
EFIS: 0524000192
DIST-CO-RTE-PM05-SLO,KER-46-60.3/60.8,0.0/0.4
Award Date12/13/2024
Closeout DateNot set
Work DescriptionVERTICAL CURVE AND EXTEND EXISTING TRUCK CLIMBING LANE.
Location DescriptionSAN LUIS OBISPO AND KERN COUNTIES NEAR CHOLAME FROM 2.0 MILES EAST OF ANTELOPE ROAD TO 0.4 MILE EAST OF THE KERN COUNTY LINE.
QA Service Level1 (Verified on 09/09/2024)

Sample Information

Sample Taken Date10/27/2025 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2026
Sample typeDispute Resolution A brief description of the sampleDispute Sample
The quantity of what the sample constitutes8 boxes From where was the sample collectedManufacturer
First name of sampler or witnessed byCarlos Last name of sampler or witnessed byManzo
Title of samplerSPM QC Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2025-10-27-52
The fabricator/manufacturer/facility namePapich Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number2
Sublot number11 HMA Mix Number39AC34LMA
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type-

Test Details

DIME Sample ID: 2025-10-27-51
DIME Test ID: 2025-10-27-51-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-01-21

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 01/15/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3998.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5649.2 g
Mass of HMA Sample prior to ignition: 1650.3 g
Mass Loss: 106.7 g
Mass of aggregate remaining after ignition: 1543.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.47 %
General comments (publicly viewable) (Max 1000 characters): RAP Does Not Comply

Test was verified on 1/21/2026