Summary for Test 2025-09-24-88-6

Test performed: ASTM D36-14ε1

Project Information

Project IdentifiersProject ID: 994116
DEA: 010J4104
EFIS: 0119000025
DIST-CO-RTE-PM01-HUM-299-30.7/33.4
Award Date11/23/2022
Closeout DateNot set
Work DescriptionProject Name: HUM-299 Curve Improvement
Location DescriptionHUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE
QA Service Level1 (Verified on 07/29/2022)

Sample Information

Sample Taken Date09/24/2025 Sample Unique Key88
Date that the sample was received by the laboratory/organization performing the testing09/26/2025 Sample typeQuality Assurance
A brief description of the samplerubber The quantity of what the sample constitutes1 can of rubber
From where was the sample collectedSource First name of sampler or witnessed byJason
Last name of sampler or witnessed byH Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMcCullough Construction Inc
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2025-09-24-88
DIME Test ID: 2025-09-24-88-6
Testing Lab: Atlas - Denver
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2025-12-30

Test Results


ASTM Thermometer used?: F
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 12/30/2025
Softening Point Sample 1: 150 F
Softening Point Sample 2: 151 F
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): SOFTENING POINT

Test was verified on 12/30/2025 ✔