Summary for Test 2025-11-12-45-4

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Sample Information

Sample Taken Date11/12/2025 Sample Unique Key45
Date that the sample was received by the laboratory/organization performing the testing11/13/2025 Sample typeQuality Control
A brief description of the sample1", 3/8", WCS The quantity of what the sample constitutes1 Bag
From where was the sample collectedJob Site First name of sampler or witnessed byTyler
Last name of sampler or witnessed byGraber Title of samplerQC Field Technician
Telephone number of sampler Laboratory sample identificationMix 180412 Set 1
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCalPortland - Tulare R/M
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier00-0000 Structure nameNW Barrier Wall End Piece
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0027
The fabricator's/manufacturer's product name for the sampleSet 1 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut
Where the material sample would have been placed if not sampledNW Barrier Wall End Piece Primary Aggregate Nominal Size1 inch
The concrete mix design number180412 Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-11-12-45
DIME Test ID: 2025-11-12-45-4
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-09-23

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Peter Rice
Date of test: 11/13/2025
Sieve SizeCumulative Percent Passing
100 %
98 %
83 %
66 %
41 %
19 %
7 %
3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/23/2026 ✔