Summary for Test 2025-11-13-5-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/13/2025 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/13/2025 |
| Sample type | Quality Assurance | A brief description of the sample | RHMA-G w/ 10% RAP Training |
| The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mathew | Last name of sampler or witnessed by | Spencer |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Doe Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-11-13-5
DIME Test ID: 2025-11-13-5-1
Testing Lab: CT D05 - Buellton Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-11-13
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Mathew Spencer
Date of test: 11/13/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3968.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 6014.1 g
Mass of HMA Sample prior to ignition: 2045.3 g
Mass Loss: 92.8 g
Mass of aggregate remaining after ignition: 1952.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.36 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.18 %
General comments (publicly viewable) (Max 1000 characters): Lx/SLx
Test was verified on 11/13/2025 ✔