Summary for Test 2025-07-30-90-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000101
DEA: 081J2904
EFIS: 0818000015
DIST-CO-RTE-PM08-RIV-215-25.0/R31.2
Award Date06/18/2024
Closeout DateNot set
Work DescriptionRHMA, HMA, REPLACE AC SURFACING, AND COLD PLANE AC PVMT.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR PERRIS FROM 0.1 MILE SOUTH OF SAN JACINTO RIVER BRIDGE TO 0.3 MILE NORTH OF RAMONA EXPRESSWAY
QA Service Level1 (Verified on 05/15/2024)

Sample Information

Sample Taken Date07/30/2025 Sample Unique Key90
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/01/2025
Sample typeAcceptance A brief description of the sample3/4" HMA-A R25 PG70-10 (PG64-16 : Virgin)
The quantity of what the sample constitutes772.24 Tons @ 23:24 From where was the sample collectedManufacturer
First name of sampler or witnessed byMartin Marietta Last name of sampler or witnessed byPlant QC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta - Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0098
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Martin Marietta Lake Elsinore Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number53417195

Test Details

DIME Sample ID: 2025-07-30-90
DIME Test ID: 2025-07-30-90-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-10-17

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Idris Najjar
Date of test: 08/04/2025
Cumulative Percent Passing
100 %
100 %
100 %
97 %
84 %
75 %
51 %
37 %
26 %
19 %
12 %
7 %
5.7 %
General comments (publicly viewable) (Max 1000 characters): Sample #2

Test was verified on 10/17/2025