Summary for Test 2025-06-27-79-5

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Sample Information

Sample Taken Date06/27/2025 Sample Unique Key79
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/28/2025
Sample typeQuality Control A brief description of the sample1", 3/8", WCS
The quantity of what the sample constitutes1 Bag From where was the sample collectedJob Site
First name of sampler or witnessed byBrian Last name of sampler or witnessed byLovett
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identificationMix 180412 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCalPortland - Redding Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0027
The fabricator's/manufacturer's product name for the sampleSet 1 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design number180412 Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-06-27-79
DIME Test ID: 2025-06-27-79-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-10-17

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: David Silva
Date of test: 06/28/2025
Sieve SizeCumulative Percent Passing
100 %
98 %
90 %
75 %
53 %
29 %
9 %
5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/17/2025