Summary for Test 2025-08-27-61-1
Test performed: ASTM D2196-Feb15Project Information
| Project Identifiers | Project ID: 1000017 DEA: 042Q7004 EFIS: 0419000040 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-4-L0.0/R14.3 |
| Award Date | 04/26/2024 |
| Closeout Date | Not set |
| Work Description | REPLACE ASPHALT CONCRETE SURFACING AND INSTALL MGS. |
| Location Description | CONTRA COSTA COUNTY IN HERCULES AND CONCORD FROM SAN PABLO AVENUE TO ROUTE 4/242 SEPARATION |
| QA Service Level | 1 (Verified on 01/08/2024) |
Sample Information
| Sample Taken Date | 08/27/2025 | Sample Unique Key | 61 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2025 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can HFST Resin |
| The quantity of what the sample constitutes | 21 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 7076245467 |
| Laboratory sample identification | 000178KBP | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | High Friction Surface Treatment | Mgf. Lot Number(s) | AZ5H01066 |
|---|---|---|---|
| Batch Number | AZ5H01066 | Mix Number | AZ5H01066 |
| Resin Binder Type | Polyester | Used for Overlay | Yes |
| Used for Inlay | No |
Test Details
DIME Sample ID: 2025-08-27-61
DIME Test ID: 2025-08-27-61-1
Testing Lab: Future Labs, LLC
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Test Release Date: 2025-10-15
Test Results
Input Type: Calculated
Tester's full name: Alex Hamilton
Date of test: 10/10/2025
Viscosity: 1664
General comments (publicly viewable) (Max 1000 characters): Gel Time (ASTM C881): 31 mins. (Does not comply)
Cure Rate (ASTM D1640): 95 mins. (Complies)
Test was verified on 10/15/2025 ✔