Summary for Test 2025-09-25-74-2

Test performed: CTM 301-March 2000

Project Information

Project IdentifiersProject ID: 994539
DEA: 021H58U4
EFIS: 0223000059
DIST-CO-RTE-PM02-PLU-70-58.2/R78.4
Award Date06/27/2023
Closeout DateNot set
Work DescriptionRECONSTRUCT ROADWAY, HMA PAVING, DRAINAGE AND ELECTRICAL WORK.
Location DescriptionPLUMAS COUNTY AT AND NEAR CROMBERG FROM GILL RANCH ROAD TO 0.2 MILE WEST OF BIG GRIZZLY CREEK BRIDGE
QA Service Level1 (Verified on 05/08/2023)

Sample Information

Sample Taken Date09/25/2025 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/29/2025
Sample typeAcceptance A brief description of the sampleGrindings
The quantity of what the sample constitutesNot Provided From where was the sample collectedJob Site
First name of sampler or witnessed byRiley Last name of sampler or witnessed byMelvin
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD80066 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMercer Fraser Transportation Laboratory (TL) Number858582
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Jobsite
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample3/4 in Class 2 Aggregate Base
The plant number A detailed description of where the material sample was collectedStockpile at PM 71.1
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-09-25-74
DIME Test ID: 2025-09-25-74-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2025-10-09

Test Results


How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 10/08/2025
As Received Gradation, Percent Passing 3 in. sieve: no data
As Received Gradation, Percent Passing 2 1/2 in. sieve: no data
As Received Gradation, Percent Passing 2 in. sieve: no data
As Received Gradation, Percent Passing 1 1/2 in. sieve: no data
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 95 %
As Received Gradation, Percent Passing 1/2 in. sieve: 83 %
As Received Gradation, Percent Passing 3/8 in. sieve: 73 %
As Received Gradation, Percent Passing #4 sieve: 50 %
As Received Gradation, Percent Passing #8 sieve: 36 %
As Received Gradation, Percent Passing #16 sieve: 26 %
As Received Gradation, Percent Passing #30 sieve: 17 %
As Received Gradation, Percent Passing #50 sieve: 11 %
As Received Gradation, Percent Passing #100 sieve: 6 %
As Received Gradation, Percent Passing #200 sieve: 4 %
As Used Gradation, Percent Passing 3 in. sieve: no data
As Used Gradation, Percent Passing 2 1/2 in. sieve: no data
As Used Gradation, Percent Passing 2 in. sieve: no data
As Used Gradation, Percent Passing 1 1/2 in. sieve: no data
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 87 %
As Used Gradation, Percent Passing 3/8 in. sieve: 77 %
As Used Gradation, Percent Passing #4 sieve: 52 %
As Used Gradation, Percent Passing #8 sieve: 38 %
As Used Gradation, Percent Passing #16 sieve: 27 %
As Used Gradation, Percent Passing #30 sieve: 18 %
As Used Gradation, Percent Passing #50 sieve: 11 %
As Used Gradation, Percent Passing #100 sieve: 7 %
As Used Gradation, Percent Passing #200 sieve: 4 %
Horizontal pressure (specimen 1): 0.16 MPa
Displacement (specimen 1): 4.75
Horizontal pressure (specimen 2): 0.11 MPa
Displacement (specimen 2): 4.15
Horizontal pressure (specimen 3): 0.1 MPa
Displacement (specimen 3): 4.1
R value (specimen 1): 75.6
R value (specimen 2): 84.4
R value (specimen 3): 85.9
R value: 83
General comments (publicly viewable) (Max 1000 characters): R=83

Test was verified on 10/9/2025