Summary for Test 2025-10-08-9-1

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 1000113
DEA: 060U5004
EFIS: 0615000300
DIST-CO-RTE-PM06-KER-5-10.2/16.0
Award Date08/29/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), HMA (TYPE A) AND RHMA (GAP GRADED).
Location DescriptionKERN COUNTY AT AND NEAR WHEELER RIDGE FROM GRAPEVINE UNDERCROSSING TO ROUTE 5/99 SEPARATION
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date10/08/2025 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/08/2025
Sample typeAcceptance A brief description of the sample100% RAP for Shoulder Backing
The quantity of what the sample constitutes1 bag of shoulder Backing From where was the sample collectedJob Site
First name of sampler or witnessed byMike Last name of sampler or witnessed byGhali
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith Edmonston Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3899098

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedWindrow in the field.
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number49 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-10-08-9
DIME Test ID: 2025-10-08-9-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-10-08

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Alex Escobar
Date of test: 10/08/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.1
Sand reading (test 1): 4.3
Clay reading (test 2): 4.9
Sand reading (test 2): 4
Clay reading (test 3): 4.9
Sand reading (test 3): 3.9
Sand equivalent (test 1): 85
Sand equivalent (test 2): 82
Sand equivalent (test 3): 80
Sand equivalent before temperature correction: 83
Sand equivalent after temperature correction: 83
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0U5004_37019_251008_shoulderbackingpdf27.83 KB10/08/20252025-10-08-9-1   Info

Test was verified on 10/8/2025