Summary for Test 2025-08-04-78-6
Test performed: AASHTO T316-22Project Information
| Project Identifiers | Project ID: 993331 DEA: 023H6904 EFIS: 0218000010 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-89-30/R42.1 |
| Award Date | 11/21/2024 |
| Closeout Date | Not set |
| Work Description | ALMANOR WEST REHAB - ROADWAY REHABILITATION |
| Location Description | IN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36. |
| QA Service Level | 1 (Verified on 10/14/2021) |
Sample Information
| Sample Taken Date | 08/04/2025 | Sample Unique Key | 78 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/25/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Binder PG 58-34 Non-Modified |
| The quantity of what the sample constitutes | 2 cans PSE | From where was the sample collected | Source |
| First name of sampler or witnessed by | Braidy | Last name of sampler or witnessed by | White |
| Title of sampler | TE | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Chester plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 858147 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-34 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | Dig it Construction, Chester Plant | |
| Certified Asphalt Supplier | Albina Asphalt (Klamath Falls Plant) - Klamath Falls OR | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-08-04-78
DIME Test ID: 2025-08-04-78-6
Testing Lab: Atlas - Denver
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-10-03
Test Results
Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Atlas
Date of test: 09/26/2025
Time of test: 00:00 HH:MM
Test Temperature: 134.9 C
Speed: 20 rpm
Spindle size: .463 in
Torque: 11.5 %
Viscosity reading #1 (A) : 287 cP
Viscosity reading #2 (B) : 287.5 cP
Viscosity reading #3 (C): 288 cP
Average viscosity : 0.288 Pa-s
General comments (publicly viewable) (Max 1000 characters): VISCOSITY
Test was verified on 10/3/2025 ✔