Summary for Test 2025-09-08-15-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000606 DEA: 081J3004 EFIS: 0818000016 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-18-90.9/R96.6 |
| Award Date | 12/06/2024 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), MOD SIGNAL & LTG SYSTEMS, & COLD PLANE AC PVMT. |
| Location Description | SAN BERNARDINO COUNTY IN AND NEAR VICTORVILLE FROM APPLE VALLEY INN ROAD TO ROUTE 15/18 SEPARATION |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 09/08/2025 | Sample Unique Key | 15 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/09/2025 |
| Sample type | Acceptance | A brief description of the sample | 3/4" HMA A R25 .6% EVO |
| The quantity of what the sample constitutes | 4 BOXES HMA, 1 QT PG64-16 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | FRANCISCO | Last name of sampler or witnessed by | RUVALCABA |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0549A-25 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Blue Diamond Victorville | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 300154 R25 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-09-08-15
DIME Test ID: 2025-09-08-15-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-09-11
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 09/10/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2170.5 g
Mass Loss: 118.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.51 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.79 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/11/2025 ✔