Summary for Test 2025-03-21-55-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994084
DEA: 060U8804
EFIS: 0616000074
DIST-CO-RTE-PM06-TUL-99-26.3/27.6
Award Date01/23/2023
Closeout DateNot set
Work DescriptionCONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY
Location DescriptionON STATE ROUTE 99
QA Service Level1 (Verified on 03/13/2023)

Sample Information

Sample Taken Date03/21/2025 Sample Unique Key55
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/21/2025
Sample typeQuality Control A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes5 From where was the sample collectedJob Site
First name of sampler or witnessed byRyan Last name of sampler or witnessed byMilum
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identificationMix 185457, Set 7 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCalPortland Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure nameAbutment 1 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number185457
The truck number from where the sample was collectedLoad 35 The batch plant ticket number from where the sample was collected0
Concrete batch plantCalPortland Tulare The fabricator/manufacturer designation for the sampleSet 7
A detailed description of where the material sample was collectedTulare Plant Where the material sample would have been placed if not sampledUnknown
From Lot No.1 Bag Lot No.1

Test Details

DIME Sample ID: 2025-03-21-55
DIME Test ID: 2025-03-21-55-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-08-02

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Kaus
Date of test: 03/28/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 61050 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 4860 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/2/2025