Summary for Test 2025-07-10-59-3

Test performed: AASHTO T275-07r12

Project Information

Project IdentifiersProject ID: 993870
DEA: 120R5604
EFIS: 1218000117
DIST-CO-RTE-PM12-ORA-5,55,73,91,133,405-var
Award Date04/12/2023
Closeout DateNot set
Work DescriptionPLACE RHMA-G, HMA, SLAB REPLACEMENT AND JPCP.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 06/14/2022)

Sample Information

Sample Taken Date07/10/2025 Sample Unique Key59
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/10/2025
Sample typeQuality Assurance A brief description of the sample3/4 RHMAG
The quantity of what the sample constitutes3/4 RHMAG From where was the sample collectedManufacturer
First name of sampler or witnessed byJimmy Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification25-0715 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-07-10-59
DIME Test ID: 2025-07-10-59-3
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2025-08-13

Test Results


Number of tests: 1
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 07/29/2025
Mass of the dry specimen in air: 1011.3 g
Mass of the dry specimen plus paraffin coating in air: 1025.8 g
Mass of the dry specimen plus paraffin coating in water: 575.0 g
Specific gravity of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Bulk Specific Gravity: 2.326
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
2025BSG-SP-0072pdf135.13 KB07/30/20252025-07-10-59-3   Info

Test was verified on 8/13/2025