Summary for Test 2025-07-17-64-1
Test performed: CTM 301-March 2000Project Information
| Project Identifiers | Project ID: 994539 DEA: 021H58U4 EFIS: 0223000059 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-58.2/R78.4 |
| Award Date | 06/27/2023 |
| Closeout Date | Not set |
| Work Description | RECONSTRUCT ROADWAY, HMA PAVING, DRAINAGE AND ELECTRICAL WORK. |
| Location Description | PLUMAS COUNTY AT AND NEAR CROMBERG FROM GILL RANCH ROAD TO 0.2 MILE WEST OF BIG GRIZZLY CREEK BRIDGE |
| QA Service Level | 1 (Verified on 05/08/2023) |
Sample Information
| Sample Taken Date | 07/17/2025 | Sample Unique Key | 64 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2025 |
| Sample type | Preliminary | A brief description of the sample | Native Borrow |
| The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | McKeehan |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | D79960 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 858578 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | WB Shoulder st.1012+50 25' Above FG | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-07-17-64
DIME Test ID: 2025-07-17-64-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2025-07-28
Test Results
How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 07/24/2025
As Received Gradation, Percent Passing 3 in. sieve: no data
As Received Gradation, Percent Passing 2 1/2 in. sieve: no data
As Received Gradation, Percent Passing 2 in. sieve: no data
As Received Gradation, Percent Passing 1 1/2 in. sieve: no data
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 100 %
As Received Gradation, Percent Passing 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 3/8 in. sieve: 100 %
As Received Gradation, Percent Passing #4 sieve: 100 %
As Received Gradation, Percent Passing #8 sieve: 99 %
As Received Gradation, Percent Passing #16 sieve: 97 %
As Received Gradation, Percent Passing #30 sieve: 93 %
As Received Gradation, Percent Passing #50 sieve: 83 %
As Received Gradation, Percent Passing #100 sieve: 56 %
As Received Gradation, Percent Passing #200 sieve: 36 %
As Used Gradation, Percent Passing 3 in. sieve: no data
As Used Gradation, Percent Passing 2 1/2 in. sieve: no data
As Used Gradation, Percent Passing 2 in. sieve: no data
As Used Gradation, Percent Passing 1 1/2 in. sieve: no data
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 3/8 in. sieve: 100 %
As Used Gradation, Percent Passing #4 sieve: 100 %
As Used Gradation, Percent Passing #8 sieve: 99 %
As Used Gradation, Percent Passing #16 sieve: 97 %
As Used Gradation, Percent Passing #30 sieve: 93 %
As Used Gradation, Percent Passing #50 sieve: 83 %
As Used Gradation, Percent Passing #100 sieve: 56 %
As Used Gradation, Percent Passing #200 sieve: 37 %
Horizontal pressure (specimen 1): 0.57 MPa
Displacement (specimen 1): 4
Horizontal pressure (specimen 2): 0.78 MPa
Displacement (specimen 2): 4.55
Horizontal pressure (specimen 3): 0.94 MPa
Displacement (specimen 3): 4.78
R value (specimen 1): 36.8
R value (specimen 2): 18.4
R value (specimen 3): 8.2
R value: 12
General comments (publicly viewable) (Max 1000 characters): R=12
Test was verified on 7/28/2025 ✔
