Summary for Test 2025-06-25-61-2

Test performed: ASTM D638-Dec14

Project Information

Project IdentifiersProject ID: 994310
DEA: 034F6504
EFIS: 0314000233
DIST-CO-RTE-PM03-YOL-50,80-0.0/2.5,4.1/R11.4
Award Date04/07/2023
Closeout DateNot set
Work DescriptionCRCP, HMA (TYPE A), RDWY EXC, CLASS 2 AB, FIBER OPTIC CABLE SYSTEMS.
Location DescriptionYOLO COUNTY IN AND NEAR WEST SACRAMENTO ON ROUTE 80 FROM 1.7 MILES EAST OF MACE BOULEVARD OVERCROSSING TO SACRAMENTO RIVER BRIDGE AND OVERHEAD (BRYTE BEND) AND ON ROUTE 50 FROM ROUTE 80 JUNCTION TO JEFFERSON BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 10/04/2022)

Sample Information

Sample Taken Date06/25/2025 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/08/2025
Sample typeQuality Control A brief description of the sample1 gallon can HFST Resin
The quantity of what the sample constitutes18 totes From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification000165KBP Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) Number25-123
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHigh Friction Surface Treatment Mgf. Lot Number(s)AZ5F00737
Batch NumberAZ5F00737 Mix NumberAZ5F00737
Resin Binder TypePolyester Used for OverlayYes
Used for InlayNo

Test Details

DIME Sample ID: 2025-06-25-61
DIME Test ID: 2025-06-25-61-2
Testing Lab: Future Labs, LLC
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2025-07-18

Test Results


Number of specimens tested: 5
Input Type: Measured
Tester's full name: Alex Hamilton
Date of test: 07/18/2025
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.145 in
Sample 1 Thickness: 0.485 in
Sample 1 Area: 0.0703 in^2
Sample 1 Ultimate Strength Actual: 272 lbs
Sample 1 percent elongation: 48 %
Sample 1 Time: 0 MM:SS
Sample 2 Width: 0.127 in
Sample 2 Thickness: 0.491 in
Sample 2 Area: 0.0624 in^2
Sample 2 Ultimate Strength Actual: 254 lbs
Sample 2 percent elongation: 57 %
Sample 2 Time: 0 MM:SS
Sample 3 Width: 0.134 in
Sample 3 Thickness: 0.486 in
Sample 3 Area: 0.0651 in^2
Sample 3 Ultimate Strength Actual: 249 lbs
Sample 3 percent elongation: 50 %
Sample 3 Time: 0 MM:SS
Sample 4 Width: 0.138 in
Sample 4 Thickness: 0.493 in
Sample 4 Area: 0.068 in^2
Sample 4 Ultimate Strength Actual: 278 lbs
Sample 4 percent elongation: 61 %
Sample 4 Time: 0 MM:SS
Sample 5 Width: 0.142 in
Sample 5 Thickness: 0.488 in
Sample 5 Area: 0.0693 in^2
Sample 5 Ultimate Strength Actual: 269 lbs
Sample 5 percent elongation: 55 %
Sample 5 Time: 0 MM:SS
Sample 1 Ultimate strength: 3869.1 psi
Sample 2 Ultimate strength : 4070.5 psi
Sample 3 Ultimate strength: 3824.9 psi
Sample 4 Ultimate strength: 4088.2 psi
Sample 5 Ultimate strength: 3881.7 psi
Ultimate Strength Average: 3947 psi
Percent Elongation Average: 54 %
General comments (publicly viewable) (Max 1000 characters): Gel Time (ASTM C881) = 17 mins. Cure Rate (ASTM D1640) = 90 mins

Test was verified on 7/18/2025