Summary for Test 2025-06-25-61-2
Test performed: ASTM D638-Dec14Project Information
| Project Identifiers | Project ID: 994310 DEA: 034F6504 EFIS: 0314000233 |
|---|---|
| DIST-CO-RTE-PM | 03-YOL-50,80-0.0/2.5,4.1/R11.4 |
| Award Date | 04/07/2023 |
| Closeout Date | Not set |
| Work Description | CRCP, HMA (TYPE A), RDWY EXC, CLASS 2 AB, FIBER OPTIC CABLE SYSTEMS. |
| Location Description | YOLO COUNTY IN AND NEAR WEST SACRAMENTO ON ROUTE 80 FROM 1.7 MILES EAST OF MACE BOULEVARD OVERCROSSING TO SACRAMENTO RIVER BRIDGE AND OVERHEAD (BRYTE BEND) AND ON ROUTE 50 FROM ROUTE 80 JUNCTION TO JEFFERSON BOULEVARD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/04/2022) |
Sample Information
| Sample Taken Date | 06/25/2025 | Sample Unique Key | 61 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/08/2025 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can HFST Resin |
| The quantity of what the sample constitutes | 18 totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 7076245467 |
| Laboratory sample identification | 000165KBP | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | 25-123 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | High Friction Surface Treatment | Mgf. Lot Number(s) | AZ5F00737 |
|---|---|---|---|
| Batch Number | AZ5F00737 | Mix Number | AZ5F00737 |
| Resin Binder Type | Polyester | Used for Overlay | Yes |
| Used for Inlay | No |
Test Details
DIME Sample ID: 2025-06-25-61
DIME Test ID: 2025-06-25-61-2
Testing Lab: Future Labs, LLC
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2025-07-18
Test Results
Number of specimens tested: 5
Input Type: Measured
Tester's full name: Alex Hamilton
Date of test: 07/18/2025
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.145 in
Sample 1 Thickness: 0.485 in
Sample 1 Area: 0.0703 in^2
Sample 1 Ultimate Strength Actual: 272 lbs
Sample 1 percent elongation: 48 %
Sample 1 Time: 0 MM:SS
Sample 2 Width: 0.127 in
Sample 2 Thickness: 0.491 in
Sample 2 Area: 0.0624 in^2
Sample 2 Ultimate Strength Actual: 254 lbs
Sample 2 percent elongation: 57 %
Sample 2 Time: 0 MM:SS
Sample 3 Width: 0.134 in
Sample 3 Thickness: 0.486 in
Sample 3 Area: 0.0651 in^2
Sample 3 Ultimate Strength Actual: 249 lbs
Sample 3 percent elongation: 50 %
Sample 3 Time: 0 MM:SS
Sample 4 Width: 0.138 in
Sample 4 Thickness: 0.493 in
Sample 4 Area: 0.068 in^2
Sample 4 Ultimate Strength Actual: 278 lbs
Sample 4 percent elongation: 61 %
Sample 4 Time: 0 MM:SS
Sample 5 Width: 0.142 in
Sample 5 Thickness: 0.488 in
Sample 5 Area: 0.0693 in^2
Sample 5 Ultimate Strength Actual: 269 lbs
Sample 5 percent elongation: 55 %
Sample 5 Time: 0 MM:SS
Sample 1 Ultimate strength: 3869.1 psi
Sample 2 Ultimate strength : 4070.5 psi
Sample 3 Ultimate strength: 3824.9 psi
Sample 4 Ultimate strength: 4088.2 psi
Sample 5 Ultimate strength: 3881.7 psi
Ultimate Strength Average: 3947 psi
Percent Elongation Average: 54 %
General comments (publicly viewable) (Max 1000 characters): Gel Time (ASTM C881) = 17 mins.
Cure Rate (ASTM D1640) = 90 mins
Test was verified on 7/18/2025 ✔