Summary for Test 2025-06-09-84-2
Test performed: CTM 301-March 2000Project Information
| Project Identifiers | Project ID: 994539 DEA: 021H58U4 EFIS: 0223000059 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-58.2/R78.4 |
| Award Date | 06/27/2023 |
| Closeout Date | Not set |
| Work Description | RECONSTRUCT ROADWAY, HMA PAVING, DRAINAGE AND ELECTRICAL WORK. |
| Location Description | PLUMAS COUNTY AT AND NEAR CROMBERG FROM GILL RANCH ROAD TO 0.2 MILE WEST OF BIG GRIZZLY CREEK BRIDGE |
| QA Service Level | 1 (Verified on 05/08/2023) |
Sample Information
| Sample Taken Date | 06/09/2025 | Sample Unique Key | 84 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2025 |
| Sample type | Acceptance | A brief description of the sample | Native Borrow |
| The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | McKeehan |
| Title of sampler | MT | Telephone number of sampler | |
| Laboratory sample identification | D79904 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Native | Transportation Laboratory (TL) Number | 802375 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Native Soil |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | WB Shoulder st. 1045+20 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-06-09-84
DIME Test ID: 2025-06-09-84-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2025-06-25
Test Results
How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 06/25/2025
As Received Gradation, Percent Passing 3 in. sieve: no data
As Received Gradation, Percent Passing 2 1/2 in. sieve: no data
As Received Gradation, Percent Passing 2 in. sieve: no data
As Received Gradation, Percent Passing 1 1/2 in. sieve: no data
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 100 %
As Received Gradation, Percent Passing 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 3/8 in. sieve: 100 %
As Received Gradation, Percent Passing #4 sieve: 100 %
As Received Gradation, Percent Passing #8 sieve: 100 %
As Received Gradation, Percent Passing #16 sieve: 98 %
As Received Gradation, Percent Passing #30 sieve: 94 %
As Received Gradation, Percent Passing #50 sieve: 88 %
As Received Gradation, Percent Passing #100 sieve: 74 %
As Received Gradation, Percent Passing #200 sieve: 57 %
As Used Gradation, Percent Passing 3 in. sieve: no data
As Used Gradation, Percent Passing 2 1/2 in. sieve: no data
As Used Gradation, Percent Passing 2 in. sieve: no data
As Used Gradation, Percent Passing 1 1/2 in. sieve: no data
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 3/8 in. sieve: 100 %
As Used Gradation, Percent Passing #4 sieve: 100 %
As Used Gradation, Percent Passing #8 sieve: 100 %
As Used Gradation, Percent Passing #16 sieve: 98 %
As Used Gradation, Percent Passing #30 sieve: 94 %
As Used Gradation, Percent Passing #50 sieve: 88 %
As Used Gradation, Percent Passing #100 sieve: 74 %
As Used Gradation, Percent Passing #200 sieve: 57 %
Horizontal pressure (specimen 1): 0.87 MPa
Displacement (specimen 1): 4.52
Horizontal pressure (specimen 2): 0.69 MPa
Displacement (specimen 2): 3.86
Horizontal pressure (specimen 3): 0.39 MPa
Displacement (specimen 3): 5.95
R value (specimen 1): 12.8
R value (specimen 2): 27.8
R value (specimen 3): 43.3
R value: 15
General comments (publicly viewable) (Max 1000 characters): R=15
Test was verified on 6/25/2025 ✔