Summary for Test 2025-05-08-7-5
Test performed: CTM 521-June 2012Project Information
| Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | Project Name: HUM-299 Curve Improvement |
| Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
| QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
| Sample Taken Date | 05/08/2025 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/09/2025 |
| Sample type | Quality Assurance | A brief description of the sample | TYPE II/V CEMENT |
| The quantity of what the sample constitutes | 2 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Laura | Last name of sampler or witnessed by | Cangas |
| Title of sampler | SR | Telephone number of sampler | 7074964358 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Eureka Ready Mix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 12-04E0056 | |
| Structure name | RW C | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | E400F |
|---|---|---|---|
| The truck number from where the sample was collected | 98 | The batch plant ticket number from where the sample was collected | 42062 |
| Concrete batch plant | Arcata Eureka Ready Mix | The fabricator/manufacturer designation for the sample | Batch |
| A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | RW C CIP lagging |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-05-08-7
DIME Test ID: 2025-05-08-7-5
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-06-19
Test Results
Number of specimens: 3
Input Type: Calculated
Tester's full name: Jamie Kelley
Date of test: 06/19/2025
Correction factor: 1
Cylinder Age: 42 days
Break Description of Cylinder 1 (if not 'cone'): 5
Break Description of Cylinder 2 (if not 'cone'): 5
Break Description of Cylinder 3 (if not 'cone'): 5
Average Compressive Strength (to nearest 10): 5000 lb/in^2
Compressive Strength of Cylinder 1: 64010 lb/in^2
Compressive Strength of Cylinder 2: 60220 lb/in^2
Compressive Strength of Cylinder 3: 64250 lb/in^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/19/2025 ✔