Summary for Test 2025-06-18-25-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000113
DEA: 060U5004
EFIS: 0615000300
DIST-CO-RTE-PM06-KER-5-10.2/16.0
Award Date08/29/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), HMA (TYPE A) AND RHMA (GAP GRADED).
Location DescriptionKERN COUNTY AT AND NEAR WHEELER RIDGE FROM GRAPEVINE UNDERCROSSING TO ROUTE 5/99 SEPARATION
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date06/18/2025 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/19/2025
Sample typeAcceptance A brief description of the sample3/4" HMA Type A w 25% RAP
The quantity of what the sample constitutesL1SL40 From where was the sample collectedSource
First name of sampler or witnessed byMike Last name of sampler or witnessed byCozad
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Solari Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number40 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-06-18-25
DIME Test ID: 2025-06-18-25-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-06-19

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Mike Cozad
Date of test: 06/19/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4241.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6321.2 g
Mass of HMA Sample prior to ignition: 2080.0 g
Mass Loss: 104.2 g
Mass of aggregate remaining after ignition: 1975.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.34 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.67 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0U5004_37039_250618_T308_L1SL40pdf81.44 KB06/19/20252025-06-18-25-2   Info

Test was verified on 6/19/2025