Summary for Test 2025-04-29-21-5

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 995446
DEA: 060X0604
EFIS: 0618000015
DIST-CO-RTE-PM06-FRE-198-0.5/19.5
Award Date05/08/2024
Closeout DateNot set
Work DescriptionREMOVE AND REPLACE CULVERTS AND CURED IN PLACE PIPELINER.
Location DescriptionFRESNO COUNTY AT VARIOUS LOCATIONS FROM 1.3 MILES WEST OF WARTHAN CREEK OVERCROSSING TO 1.7 MILES WEST OF FIRESTONE AVENUE
QA Service Level1 (Verified on 11/16/2023)

Sample Information

Sample Taken Date04/29/2025 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/29/2025
Sample typeQuality Control A brief description of the sampleConcrete Test Samples
The quantity of what the sample constitutes9 4x8 Cylinders From where was the sample collectedManufacturer
First name of sampler or witnessed byDonald Last name of sampler or witnessed byJuneman
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePrecast Unlimited Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCT675SL
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected101092
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-04-29-21
DIME Test ID: 2025-04-29-21-5
Testing Lab: Precast Unlimited Inc.
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-06-18

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Donald Juneman
Date of test: 06/10/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 8.5 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 62450 lb
Maximum load on cylinder 2: 61120 lb
Maximum load on cylinder 3: 64810 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.56 in^2
Cross sectional area of cylinder 2: 12.56 in^2
Cross sectional area of cylinder 3: 12.56 in^2
Compressive strength (to nearest 10 psi): 5000 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/18/2025