Summary for Test 2025-05-23-32-2

Test performed: CTM 301-March 2000

Project Information

Project IdentifiersProject ID: 994539
DEA: 021H58U4
EFIS: 0223000059
DIST-CO-RTE-PM02-PLU-70-58.2/R78.4
Award Date06/27/2023
Closeout DateNot set
Work DescriptionRECONSTRUCT ROADWAY, HMA PAVING, DRAINAGE AND ELECTRICAL WORK.
Location DescriptionPLUMAS COUNTY AT AND NEAR CROMBERG FROM GILL RANCH ROAD TO 0.2 MILE WEST OF BIG GRIZZLY CREEK BRIDGE
QA Service Level1 (Verified on 05/08/2023)

Sample Information

Sample Taken Date05/23/2025 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing05/27/2025 Sample typeAcceptance
A brief description of the sample2 bags 3/4-inch Class 2 Aggregate Base, Field No. 2025-1 The quantity of what the sample constitutesStockpile @ STA 745+00
From where was the sample collectedJob Site First name of sampler or witnessed byJeff
Last name of sampler or witnessed byMcKeehan Title of samplerMT
Telephone number of sampler Laboratory sample identificationD79895
Linked DIME Sample ID The fabricator/manufacturer/facility nameUndeclared
Transportation Laboratory (TL) Number802373 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid Item3863350

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Undeclared
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ 745+00
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-05-23-32
DIME Test ID: 2025-05-23-32-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2025-06-12

Test Results


How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 06/11/2025
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 99 %
As Received Gradation, Percent Passing 1/2 in. sieve: 77 %
As Received Gradation, Percent Passing 3/8 in. sieve: 64 %
As Received Gradation, Percent Passing #4 sieve: 43 %
As Received Gradation, Percent Passing #8 sieve: 31 %
As Received Gradation, Percent Passing #16 sieve: 24 %
As Received Gradation, Percent Passing #30 sieve: 19 %
As Received Gradation, Percent Passing #50 sieve: 16 %
As Received Gradation, Percent Passing #100 sieve: 12 %
As Received Gradation, Percent Passing #200 sieve: 9.3 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 78 %
As Used Gradation, Percent Passing 3/8 in. sieve: 64 %
As Used Gradation, Percent Passing #4 sieve: 43 %
As Used Gradation, Percent Passing #8 sieve: 31 %
As Used Gradation, Percent Passing #16 sieve: 24 %
As Used Gradation, Percent Passing #30 sieve: 19 %
As Used Gradation, Percent Passing #50 sieve: 16 %
As Used Gradation, Percent Passing #100 sieve: 12 %
As Used Gradation, Percent Passing #200 sieve: 9 %
Horizontal pressure (specimen 1): 0.1 MPa
Displacement (specimen 1): 5.09
Horizontal pressure (specimen 2): 0.11 MPa
Displacement (specimen 2): 5.11
Horizontal pressure (specimen 3): 0.08 MPa
Displacement (specimen 3): 4.64
R value (specimen 1): 83.1
R value (specimen 2): 81.5
R value (specimen 3): 87.3
R value: 84
General comments (publicly viewable) (Max 1000 characters): R=84

Test was verified on 6/12/2025 ✔