Summary for Test 2025-05-29-5-2
Test performed: ASTM A775-19Project Information
| Project Identifiers | Project ID: 994525 DEA: 031H9904 EFIS: 0317000043 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA,NEV-80-68.3/69.7,0.0/R2.7 |
| Award Date | 11/07/2023 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, PLACE HMA & JPCP, SLAB REPLACEMENT & POLYESTER CONC OVERLAY. |
| Location Description | PLACER AND NEVADA COUNTIES NEAR KINGVALE FROM 0.3 MILE WEST OF TROY UNDERCROSSING TO 0.2 MILE EAST OF SODA SPRINGS OVERCROSSING |
| QA Service Level | 1 (Verified on 05/15/2023) |
Sample Information
| Sample Taken Date | 05/29/2025 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/03/2025 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM 775 Epoxy Coated Bar | The quantity of what the sample constitutes | 2 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Levi |
| Last name of sampler or witnessed by | Pivoda | Title of sampler | Associate Steel Inspector |
| Telephone number of sampler | 9152961871 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Western Coating | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S88-529-25 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 016525 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | CH3374UX | Rebar Coating Specification | ASTM A775 |
| Rebar Size (#) | #4 | Rebar Coating Color | Green |
| Rebar Manufacturer | Cascade Steel Rolling Mills Inc | Rebar Coater | Western Coating in Oregon |
| Rebar Powder Manufacturer | Release Number | ||
| Quality Assurance Code |
Test Details
DIME Sample ID: 2025-05-29-5
DIME Test ID: 2025-05-29-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Test Release Date: 2025-06-11
Test Results
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 06/10/2025
Total Number of Holiday: 1
Total Length: 5
Holidays Per Linear Foot of Bar: 0.2
Holiday Test Pass/Fail: Pass
Bend Test Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/11/2025 ✔