Summary for Test 2025-05-08-5-1
Test performed: ASTM A775-19Project Information
| Project Identifiers | Project ID: 1000004 DEA: 033H5604 EFIS: 0318000014 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA,NEV-20,80-VAR |
| Award Date | 05/10/2024 |
| Closeout Date | Not set |
| Work Description | STRUCTURAL CONC, BAR REINFORCING STEEL, BRIDGE REMOVAL, HMA, AND JPCP. |
| Location Description | PLACER AND NEVADA COUNTIES NEAR CISCO GROVE ON ROUTE 80 FROM 0.4 MILE WEST OF LAKE VALLEY OVERCROSSING TO 0.9 MILE EAST OF YUBA PASS SEPARATION AND OVERHEAD AND ON ROUTE 20 AT YUBA PASS SEPARATION AND OVERHEAD |
| QA Service Level | 1 (Verified on 01/18/2024) |
Sample Information
| Sample Taken Date | 05/08/2025 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/12/2025 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM A706 Grade 60 #3 size rebar - epoxy coated - ASTM A775 |
| The quantity of what the sample constitutes | 3,555 LBS | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
| Title of sampler | Telephone number of sampler | 7073428602 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Western Coatings Ogden, UT | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-004-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 283924, 284024, 284124 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | CH1414WL, CH3374UX | Rebar Coating Specification | ASTM A775 |
| Rebar Size (#) | 3 | Rebar Coating Color | Green |
| Rebar Manufacturer | Cascade Steel Oregon | Rebar Coater | Western Coatings Eugene OR |
| Rebar Powder Manufacturer | Sherwin Williams | Release Number | 117 |
| Quality Assurance Code |
Test Details
DIME Sample ID: 2025-05-08-5
DIME Test ID: 2025-05-08-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Test Release Date: 2025-05-30
Test Results
Input Type: Calculated
Tester's full name: Willie Torres
Date of test: 05/23/2025
Holidays Per Linear Foot of Bar: 0 holiday pe
Holiday Test Pass/Fail: Pass
Bend Test Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters): Tested by Atlas lab
Test was verified on 5/30/2025 ✔