Summary for Test 2025-04-30-61-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994084 DEA: 060U8804 EFIS: 0616000074 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-26.3/27.6 |
| Award Date | 01/23/2023 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT A NEW INTERCHANGE AT COMMERCIAL AVENUE NOW CALLED INTERNATIONAL AGRI-CENTER WAY |
| Location Description | ON STATE ROUTE 99 |
| QA Service Level | 1 (Verified on 03/13/2023) |
Sample Information
| Sample Taken Date | 04/30/2025 | Sample Unique Key | 61 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/01/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
| The quantity of what the sample constitutes | Concrete Cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Structures Rep | Last name of sampler or witnessed by | Structures Rep |
| Title of sampler | Structures Rep | Telephone number of sampler | |
| Laboratory sample identification | 13 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Cal Portland Tulare | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 18545R |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Not Supplied | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | On Job Site at Concrete Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-04-30-61
DIME Test ID: 2025-04-30-61-1
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-05-14
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 05/09/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 51580 lb
Maximum load on cylinder 2: 49350 lb
Maximum load on cylinder 3: 50180 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 9 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4103.4 psi
Compressive strength of cylinder 2: 3907.4 psi
Compressive strength of cylinder 3: 3973.1 psi
Compressive strength (to nearest 10 psi): 3990 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/14/2025 ✔