Summary for Test 2025-04-19-7-5

Test performed: CTM 389-19

Project Information

Project IdentifiersProject ID: 994310
DEA: 034F6504
EFIS: 0314000233
DIST-CO-RTE-PM03-YOL-50,80-0.0/2.5,4.1/R11.4
Award Date04/07/2023
Closeout DateNot set
Work DescriptionCRCP, HMA (TYPE A), RDWY EXC, CLASS 2 AB, FIBER OPTIC CABLE SYSTEMS.
Location DescriptionYOLO COUNTY IN AND NEAR WEST SACRAMENTO ON ROUTE 80 FROM 1.7 MILES EAST OF MACE BOULEVARD OVERCROSSING TO SACRAMENTO RIVER BRIDGE AND OVERHEAD (BRYTE BEND) AND ON ROUTE 50 FROM ROUTE 80 JUNCTION TO JEFFERSON BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 10/04/2022)

Sample Information

Sample Taken Date04/19/2025 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2025
Sample typeProduction Start-Up A brief description of the sample10 Boxes
The quantity of what the sample constitutes3/4" RHMA From where was the sample collectedSource
First name of sampler or witnessed byDustan Last name of sampler or witnessed byKliethermes
Title of sampler Telephone number of sampler
Laboratory sample identificationDaily 25-031 Linked DIME Sample ID2025-04-19-4
The fabricator/manufacturer/facility nameTeichert Perkins Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number4
Sublot number1 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-04-19-7
DIME Test ID: 2025-04-19-7-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-05-08

Test Results


Specified number of passes at 12.7 mm: 25000
Specimen Preparation Method:
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 05/07/2025
Average impression at 5000 passes (left/right avg): 1.56 mm
Average impression at 10000 passes (left/right avg): 2.05 mm
Average impression at 15000 passes (left/right avg): 2.245 mm
Average impression at 20000 passes (left/right avg): 2.41 mm
Average impression at 25000 passes (left/right avg): 2.535 mm
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/8/2025