Summary for Test 2017-10-03-1-6
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-180-R74.1/R78.6 |
| Award Date | 04/05/2017 |
| Closeout Date | 07/06/2021 |
| Work Description | CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY |
| Location Description | FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE |
| QA Service Level | 1 (Verified on 07/10/2017) |
Sample Information
| Sample Taken Date | 10/03/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/04/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Resistance Butt Welded Hoops |
| The quantity of what the sample constitutes | 150 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
| Title of sampler | Unknown | Telephone number of sampler | 707-310-2029 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-313-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 593421 |
| Hoop Manufacturer Lot Number(s) | H01,H02 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 5 |
| Diameter of Hoop | 2'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Evraz |
| Welding Company | Harris Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-10-03-1
DIME Test ID: 2017-10-03-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-10-13
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/06/2017
UTM: 75KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | H02 | #5/16mm | 0.31 | 28281 | 91230 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 10/6/2017 ✔