Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-10-03-1
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-R74.1/R78.6 |
Award Date | 04/05/2017 |
Closeout Date | 07/06/2021 |
Work Description | CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY |
Location Description | FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE |
QA Service Level | 1 (Verified on 07/10/2017) |
Sample Information
Sample Taken Date | 10/03/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/04/2017 |
Sample type | Quality Assurance | A brief description of the sample | Resistance Butt Welded Hoops |
The quantity of what the sample constitutes | 150 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | 707-310-2029 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-313-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 593421 |
Hoop Manufacturer Lot Number(s) | H01,H02 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 5 |
Diameter of Hoop | 2'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Evraz |
Welding Company | Harris Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-10-03-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-6 CTM 670-December 2013 (Verified)