Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-10-03-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210618
DEA: 06342534
EFIS: 0600000382
COOP: 061616A2
DIST-CO-RTE-PM06-FRE-180-R74.1/R78.6
Award Date04/05/2017
Closeout Date07/06/2021
Work DescriptionCONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY
Location DescriptionFRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE
QA Service Level1 (Verified on 07/10/2017)

Sample Information

Sample Taken Date10/03/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/04/2017
Sample typeQuality Assurance A brief description of the sample Resistance Butt Welded Hoops
The quantity of what the sample constitutes150 From where was the sample collectedManufacturer
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of sampler707-310-2029
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB10-313-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)593421
Hoop Manufacturer Lot Number(s)H01,H02 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerEvraz
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-10-03-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/2017Fred
Yes
10/13/2017necking okay
2017-10-03-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/2017Fred
Yes
10/13/2017necking okay
2017-10-03-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/2017Fred
Yes
10/13/2017necking okay
2017-10-03-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/2017Fred
Yes
10/13/2017necking okay
2017-10-03-1-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/2017Fred
Yes
10/13/2017necking okay
2017-10-03-1-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/06/2017Fred
Yes
10/13/2017necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-10-03-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-03-1-6 CTM 670-December 2013 (Verified)