Summary for Test 2025-04-05-7-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994588
DEA: 081H3904
EFIS: 0817000032
DIST-CO-RTE-PM08-SBD-15-R20.5/R21.6,R25.5/R30.7
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCONSTRUCT BUILDING, ROADWAY EXC, JPCP, AND TEMPORARY BARRIER SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF CLEGHORN ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF ROUTE 138 AND FROM 0.5 MILE SOUTH OF TRUCK SAFETY CHECK AREA TO 0.4 MILE NORTH OF OAK HILL ROAD OVERCROSSING
QA Service Level1 (Verified on 08/02/2023)

Sample Information

Sample Taken Date04/05/2025 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing04/09/2025 Sample typeAcceptance
A brief description of the sample3/4" HMA A SP R15 The quantity of what the sample constitutes6 BOXES OF HMA
From where was the sample collectedManufacturer First name of sampler or witnessed byVICTOR
Last name of sampler or witnessed byCAPACETE Title of sampler
Telephone number of sampler Laboratory sample identification0199A-25
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105927
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-04-05-7
DIME Test ID: 2025-04-05-7-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-04-14

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Ayman Nabulsi
Date of test: 04/10/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2143.6 g
Mass Loss: 101.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.02 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.56 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/14/2025 ✔