Summary for Test 2025-02-24-12-6

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000216
DEA: 081G6304
EFIS: 0816000043
DIST-CO-RTE-PM08-RIV-111-47.2/55.3
Award Date09/05/2024
Closeout DateNot set
Work DescriptionRHMA-G, REPLACE AC SURFACING, AND COLD PLANE AC PVMT.
Location DescriptionRIVERSIDE COUNTY IN PALM SPRINGS FROM GOLF CLUB DRIVE TO WEST GATEWAY DRIVE
QA Service Level1 (Verified on 05/15/2024)

Sample Information

Sample Taken Date02/24/2025 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/26/2025
Sample typeProduction Start-Up A brief description of the sample3/4" RHMA G SP .50% LAS
The quantity of what the sample constitutes22 BX RHMA 2 BG CMB AG 1 BG HN 1 BG RC 4 QT PG64-165 QT RBR BLND 2 QT RFX From where was the sample collectedManufacturer
First name of sampler or witnessed byTONY Last name of sampler or witnessed byPRICE
Title of sampler Telephone number of sampler
Laboratory sample identification0142G-25 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Desert Hot Springs Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number1556
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-02-24-12
DIME Test ID: 2025-02-24-12-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-03-21

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Eddie Bidinger
Date of test: 03/01/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2180.6 g
Mass Loss: 164.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.05 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.06 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.45 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2025